Clark Air Systems Clark Air Systems
Equipment Air Filters Industries Served Case Studies Resources Contact Us
Select

Select

Automotive Refinish
Affordable and Versatile Spray Booth Solutions

Global Finishing Solutions Select Spray booths surpass all others in their class. Body Shops looking for a quality, user-friendly, and affordable spray booth, should look no further than the Select spray booth models. Available in all popular airflow types, and with multiple options, the Select line offers unequaled value and quality.
 


 

Select Control Panels:
PLC Equipped and UL listed

GFS control panels are factory assembled and tested. Control wires are numbered for easy identification. Components are labeled to match electrical schematics and panels include terminal strip for field wiring.
All heated booths are equipped with state-of-the-art PLC controls.
Control packages are available for non-heated booths.

Touch screen PLC controls are optional
Large, solvent resistant, high-contrast graphic display with help menus.

Standard Control Panel

____________________Optional Touch-Screen Panel

Select Air Heater:





Select Air Heater:

Placement Options:
Select Air Heaters are designed for vertical or horizontal placement. Heaters are available in three models:

•Standard Heater with VFD
•Forced-Dry Curing Heater with Dual VFD
•Recirculating (90/10) Curing Heater with VFD

ALL HEATED BOOTHS INCLUDE SINGLE OR DUAL VFDS FOR BETTER PERFORMANCE AND ENERGY SAVINGS.


Features:
Versatility
-
available as vertical or horizontal mount
-unit will deliver 12,600 CFM
Temperature rise up to 100
°F - Standard Heater
Energy efficient Forced Dry and Recirculating heaters are available
ANSI standard gas train sized for 7"-14" natural gas pressure
Comes equipped with a 10 HP 3-phase motor
ETL Listed
G-90 galvanized enclosure
Ready for indoor/outdoor use (with optional outdoor kit)
Equipped with an enclosed stand for vertical configuration
-Air intake from any side
Horizontal units are equipped with an intake hood and filter
Interior lined for rigidity and future high-temp application
Motor is mounted out of the airstream for easy access
Discharge can be on top or side of vertical units
Discharge can be at the end or bottom on horizontal units
All paint booth controls mounted in air make up control section
Main disconnect
Standard voltages: 208-230-480 Volt, 3-phase
Pre-wired remote PLC control panel with digital display
Exhaust unit VFD
Booth airflow balance control

 

Select Downdraft:
High-Performance airflow design
*Floor exhaust pit required

Downdraft airflow provides the optimum airflow for overspray removal. Air is drawn through the ceiling filters, over the vehicle, and is exhausted through a pit in the floor. All overspray is safely contained in the pit filters.

Cabin Specifications:

Non-Pressurized:
Internal: 26'l x 14'w x 9'h
External: 26'4"l x 14'4"w x 9'2"h
2-Wing Frontal: 10'w x 9'h

Pressurized:
Internal: 26'l x 14'w x 9'h
External: 26'4"l x 14'4"w x 11'4"h
2-Wing Frontal: 10'w x 9'h

Construction:
-Downdraft airflow during spray and cure cycles
-Single-row exhaust pit (21'4" long)
-G-90 galvanized steel

Doors:
-10'w x 9"h 2-wing entrance door (10'w x 8'10"h opening)
-1 Personnel access door

Lighting
-ETL-Listed inside-accessible light fixtures 102/277v
-(10) 4-tube light fixtures
-Energy-efficient electronic ballasts
-T-8 Color-corrected fluorescent tubes

Exhaust System:
-(1) 34" Tube-axial Fan
-(1) 5hp EPACT Motor
-12,600 CFM @ 3/4" SP
-Booth pressure manometer gauge

Filtration:
-High-efficiency, high-temperature compatible ceiling filter media
-high holding capacity filter media in pit

White pre-coated panels are optional



Select Side-Downdraft:
Downdraft airflow with no pit required


The ideal solution for shops where digging a pit is not an option. Side-Downdraft booths provide excellent overspray removal in an innovative design. Air is drawn through the ceiling, over the vehicle, and is exhausted through exhaust chambers on either side of the booth.

Cabin Specifications:

Non-Pressurized:
Internal: 26'l x 14'w x 9'h
External: 26'4"l x 16'8"w x 9'2"h
2-Wing Frontal: 10'w x 9'h

Pressurized:
Internal: 26'l x 14'w x 9'h
External: 26'4"l x 16'8"w x 11'4"h
2-Wing Frontal: 10'w x 9'h

Construction:
-Side-Downdraft airflow during spray and cure cycles
-No pit excavation required
-G-90 galvanized steel

Doors:
-10'w x 9"h 2-wing entrance door (10'w x 8'10"h opening)
-1 Personnel access door


Lighting
-ETL-Listed inside-accessible light fixtures 102/277v
-(10) 4-tube light fixtures
-Energy-efficient electronic ballasts
-T-8 Color-corrected fluorescent tubes

Exhaust System:
-(2) 24" tube-axial Fans
-(2) 2hp EPACT Motors
-12,600 CFM @ 3/4" SP
-Booth pressure manometer gauge

Filtration:
-High-efficiency, high-temperature compatible ceiling filter media
-High holding capacity filter media in exhaust boxes

White pre-coated panels are optional

 

Select Semi-Downdraft:
Proven airflow designed in an economical package

Semi-Downdraft booths fit a variety of unique shop layouts where pits for downdaft booths just aren't feasible. Air is drawn through the ceiling, over the vehicle, and is exhausted through an exhaust chamber at the rear of the booth.

Cabin Specifications:

Non-Pressurized:

Internal: 26'l x 14'w x 9'h
External: 26'4"l x 14'4"w x 10'2"h
2-Wing Frontal: 10'w x 9'h

Pressurized:
Internal: 26'l x 14'w x 9'h
External: 26'4"l x 14'4"w x 11'4"h
2-Wing Frontal: 10'w x 9'h

Construction:
-Semi-downdraft airflow during spray cycles and cure cycles
-No pit excavation required
-G-90 galvanized steel

Doors:
-10'w x 9"h 2-wing entrance door (10'w x 8'10"h opening)
-1 Personnel access door

Lighting
-ETL-Listed inside-accessible light fixtures 102/277v
-(10) 4-tube light fixtures
-Energy-efficient electronic ballasts
-T-8 Color-corrected fluorescent tubes

Exhaust System:
-(1) 34" Tube-axial Fan
-(1) 3hp EPACT Motor
-10,500 CFM @ 3/8" SP
-Booth pressure manometer gauge

Filtration:
-High-efficiency, high-temperature compatible ceiling filter media
-High holding capacity filter media in exhaust boxes

White pre-coated are optional



Select Crossdraft:
Classic spray booth design

Crossdraft booths are popular throughout the world. Simple, reliable, and extremely economical, Crossdraft booths fit any type of operation, large or small. Air is drawn through the front of the booth, over the vehicle, and is exhausted through an exhaust chamber at the rear of the booth.

Cabin Specifications:

Non-Pressurized:
Internal: 26'l x 14'w x 9'h
External: 26'4"l x 14'4"w x 10'2"h
2-Wing Frontal: 10'w x 9'h

Pressurized:
Internal: 26'l x 14'w x 9'h
External: 26'4"l x 14'4"w x 10'2"h
2-Wing Frontal: 10'w x 9'h

Construction:
-Crossdraft airflow during spray and cure cycles
-No pit excavation required
-G-90 galvanized steel

Doors:
-10'w x 9"h 2-wing entrance door (10'w x 8'10"h opening)
-1 Personnel access door

Lighting
-ETL-Listed inside-accessible light fixtures 102/277v
-(10) 4-tube light fixtures
-Energy-efficient electronic ballasts
-T-8 Color-corrected fluorescent tubes

Exhaust System:
-(1) 34" Tube-axial Fan
-(1) 3hp EPACT Motor
-12,600 CFM @ 3/4" SP
-Booth pressure manometer gauge

Filtration:
-High-efficiency, door filter media
-High holding capacity filter media in exhaust boxes

White pre-coated panels are optional
 

Options:

Options available on all select spray booths:
Drive-Thru Configurations
-Easier movement of vehicles through the booth
-Improve workflow in your shop
Observation windows
Control packages
White coated panels
Ductwork packages
Single phase motors

Air Heater Options:
-Single-phase motors
-Auto-Balance (pressure)
-Recirculating Cure mode
-Touch-screen PLC remote control panel
-Propane fuel burner
-Intake baffle and diffuser


Code Compliance:

The Select line of Spray Booths conforms to the requirements of:
NFPA-33 Standard for spray application using flammable or combustible materials
NFPA-86 Standard for ovens and furnaces
NFPA-91 Standard for exhaust systems for air conveying of materials
NFPA-101 Life Safety Code
NFPA-70 National Electric Code
OSHA Safety and Health Standards (29 CFR 1910, 1910.107)
IFC International Fire Code
IBC International Building Code
IMC International Mechanical Code
BOCA National Fire Prevention Code; National Building Code; National Mechanical Code
UFC Uniform Fire Code
UBC Uniform Building Code
UMC Uniform Mechanical Code
SBCCI Standard Fire Prevention Code; Standard Building Code; Standard Mechanical Cod
Call 800-367-0062