Automotive Refinish Affordable and Versatile Spray Booth Solutions Global Finishing Solutions Select Spray booths surpass all others in their class. Body Shops looking for a quality, user-friendly, and affordable spray booth, should look no further than the Select spray booth models. Available in all popular airflow types, and with multiple options, the Select line offers unequaled value and quality. | |  |
 | |  |
| Select Control Panels: PLC Equipped and UL listed GFS control panels are factory assembled and tested. Control wires are numbered for easy identification. Components are labeled to match electrical schematics and panels include terminal strip for field wiring. All heated booths are equipped with state-of-the-art PLC controls. Control packages are available for non-heated booths. Touch screen PLC controls are optional Large, solvent resistant, high-contrast graphic display with help menus. |
| Standard Control Panel  ____________________Optional Touch-Screen Panel |
| |
| |
Select Air Heater:  |
| Select Air Heater: Placement Options: Select Air Heaters are designed for vertical or horizontal placement. Heaters are available in three models: •Standard Heater with VFD •Forced-Dry Curing Heater with Dual VFD •Recirculating (90/10) Curing Heater with VFD ALL HEATED BOOTHS INCLUDE SINGLE OR DUAL VFDS FOR BETTER PERFORMANCE AND ENERGY SAVINGS. Features: Versatility -available as vertical or horizontal mount -unit will deliver 12,600 CFM Temperature rise up to 100°F - Standard Heater Energy efficient Forced Dry and Recirculating heaters are available ANSI standard gas train sized for 7"-14" natural gas pressure Comes equipped with a 10 HP 3-phase motor ETL Listed G-90 galvanized enclosure Ready for indoor/outdoor use (with optional outdoor kit) Equipped with an enclosed stand for vertical configuration -Air intake from any side Horizontal units are equipped with an intake hood and filter Interior lined for rigidity and future high-temp application Motor is mounted out of the airstream for easy access Discharge can be on top or side of vertical units Discharge can be at the end or bottom on horizontal units All paint booth controls mounted in air make up control section Main disconnect Standard voltages: 208-230-480 Volt, 3-phase Pre-wired remote PLC control panel with digital display Exhaust unit VFD Booth airflow balance control |
 | |  |
| Select Downdraft: High-Performance airflow design *Floor exhaust pit required Downdraft airflow provides the optimum airflow for overspray removal. Air is drawn through the ceiling filters, over the vehicle, and is exhausted through a pit in the floor. All overspray is safely contained in the pit filters. Cabin Specifications: Non-Pressurized: Internal: 26'l x 14'w x 9'h External: 26'4"l x 14'4"w x 9'2"h 2-Wing Frontal: 10'w x 9'h Pressurized: Internal: 26'l x 14'w x 9'h External: 26'4"l x 14'4"w x 11'4"h 2-Wing Frontal: 10'w x 9'h Construction: -Downdraft airflow during spray and cure cycles -Single-row exhaust pit (21'4" long) -G-90 galvanized steel Doors: -10'w x 9"h 2-wing entrance door (10'w x 8'10"h opening) -1 Personnel access door Lighting -ETL-Listed inside-accessible light fixtures 102/277v -(10) 4-tube light fixtures -Energy-efficient electronic ballasts -T-8 Color-corrected fluorescent tubes Exhaust System: -(1) 34" Tube-axial Fan -(1) 5hp EPACT Motor -12,600 CFM @ 3/4" SP -Booth pressure manometer gauge Filtration: -High-efficiency, high-temperature compatible ceiling filter media -high holding capacity filter media in pit White pre-coated panels are optional |
| Select Side-Downdraft: Downdraft airflow with no pit required The ideal solution for shops where digging a pit is not an option. Side-Downdraft booths provide excellent overspray removal in an innovative design. Air is drawn through the ceiling, over the vehicle, and is exhausted through exhaust chambers on either side of the booth. Cabin Specifications: Non-Pressurized: Internal: 26'l x 14'w x 9'h External: 26'4"l x 16'8"w x 9'2"h 2-Wing Frontal: 10'w x 9'h Pressurized: Internal: 26'l x 14'w x 9'h External: 26'4"l x 16'8"w x 11'4"h 2-Wing Frontal: 10'w x 9'h Construction: -Side-Downdraft airflow during spray and cure cycles -No pit excavation required -G-90 galvanized steel Doors: -10'w x 9"h 2-wing entrance door (10'w x 8'10"h opening) -1 Personnel access door Lighting -ETL-Listed inside-accessible light fixtures 102/277v -(10) 4-tube light fixtures -Energy-efficient electronic ballasts -T-8 Color-corrected fluorescent tubes Exhaust System: -(2) 24" tube-axial Fans -(2) 2hp EPACT Motors -12,600 CFM @ 3/4" SP -Booth pressure manometer gauge Filtration: -High-efficiency, high-temperature compatible ceiling filter media -High holding capacity filter media in exhaust boxes White pre-coated panels are optional |
 | |  |
| Select Semi-Downdraft: Proven airflow designed in an economical package Semi-Downdraft booths fit a variety of unique shop layouts where pits for downdaft booths just aren't feasible. Air is drawn through the ceiling, over the vehicle, and is exhausted through an exhaust chamber at the rear of the booth. Cabin Specifications: Non-Pressurized: Internal: 26'l x 14'w x 9'h External: 26'4"l x 14'4"w x 10'2"h 2-Wing Frontal: 10'w x 9'h Pressurized: Internal: 26'l x 14'w x 9'h External: 26'4"l x 14'4"w x 11'4"h 2-Wing Frontal: 10'w x 9'h Construction: -Semi-downdraft airflow during spray cycles and cure cycles -No pit excavation required -G-90 galvanized steel Doors: -10'w x 9"h 2-wing entrance door (10'w x 8'10"h opening) -1 Personnel access door Lighting -ETL-Listed inside-accessible light fixtures 102/277v -(10) 4-tube light fixtures -Energy-efficient electronic ballasts -T-8 Color-corrected fluorescent tubes Exhaust System: -(1) 34" Tube-axial Fan -(1) 3hp EPACT Motor -10,500 CFM @ 3/8" SP -Booth pressure manometer gauge Filtration: -High-efficiency, high-temperature compatible ceiling filter media -High holding capacity filter media in exhaust boxes White pre-coated are optional |
| Select Crossdraft: Classic spray booth design Crossdraft booths are popular throughout the world. Simple, reliable, and extremely economical, Crossdraft booths fit any type of operation, large or small. Air is drawn through the front of the booth, over the vehicle, and is exhausted through an exhaust chamber at the rear of the booth. Cabin Specifications: Non-Pressurized: Internal: 26'l x 14'w x 9'h External: 26'4"l x 14'4"w x 10'2"h 2-Wing Frontal: 10'w x 9'h Pressurized: Internal: 26'l x 14'w x 9'h External: 26'4"l x 14'4"w x 10'2"h 2-Wing Frontal: 10'w x 9'h Construction: -Crossdraft airflow during spray and cure cycles -No pit excavation required -G-90 galvanized steel Doors: -10'w x 9"h 2-wing entrance door (10'w x 8'10"h opening) -1 Personnel access door Lighting -ETL-Listed inside-accessible light fixtures 102/277v -(10) 4-tube light fixtures -Energy-efficient electronic ballasts -T-8 Color-corrected fluorescent tubes Exhaust System: -(1) 34" Tube-axial Fan -(1) 3hp EPACT Motor -12,600 CFM @ 3/4" SP -Booth pressure manometer gauge Filtration: -High-efficiency, door filter media -High holding capacity filter media in exhaust boxes White pre-coated panels are optional |
 | |  |
| Options: Options available on all select spray booths: Drive-Thru Configurations -Easier movement of vehicles through the booth -Improve workflow in your shop Observation windows Control packages White coated panels Ductwork packages Single phase motors Air Heater Options: -Single-phase motors -Auto-Balance (pressure) -Recirculating Cure mode -Touch-screen PLC remote control panel -Propane fuel burner -Intake baffle and diffuser |
| Code Compliance: The Select line of Spray Booths conforms to the requirements of: NFPA-33 Standard for spray application using flammable or combustible materials NFPA-86 Standard for ovens and furnaces NFPA-91 Standard for exhaust systems for air conveying of materials NFPA-101 Life Safety Code NFPA-70 National Electric Code OSHA Safety and Health Standards (29 CFR 1910, 1910.107) IFC International Fire Code IBC International Building Code IMC International Mechanical Code BOCA National Fire Prevention Code; National Building Code; National Mechanical Code UFC Uniform Fire Code UBC Uniform Building Code UMC Uniform Mechanical Code SBCCI Standard Fire Prevention Code; Standard Building Code; Standard Mechanical Cod |